Dissolve oxygen meter
Dissolve oxygen meter

Dissolve oxygen meter

MOQ : 1 Piece

Dissolve oxygen meter Specification

  • Temperature Range
  • 0C to 50C
  • Response Time
  • Less than 60 seconds
  • Circuit Type
  • Electronic
  • Automation Grade
  • Manual
  • Protection Level
  • IP54
  • Number of Module
  • Single
  • Rated Voltage
  • DC 9V (Battery operated)
  • Finish Type
  • Matte
  • Product Type
  • Dissolved Oxygen Meter
  • Material
  • ABS Plastic
  • Operating Temperature
  • 0C to 50C
  • Size
  • Main Unit: 70 x 135 x 45 mm
  • Color
  • Blue/White
  • Weight
  • Approx. 250 g
  • Mounting Type
  • Handheld
  • Calibration
  • Manual, One or Two Point
  • DO Accuracy
  • 0.4 mg/L
  • Application
  • Water Quality Testing, Aquaculture, Laboratory, Research
  • Display Type
  • LCD Digital Display
  • Resolution
  • 0.1 mg/L
  • Temperature Compensation
  • Automatic (ATC)
  • Power Supply
  • 9V Battery
  • Electrode Type
  • Polarographic DO Probe
  • DO Measurement Range
  • 0 to 20.0 mg/L (ppm)
 

Dissolve oxygen meter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

Dissolve oxygen meter About



Pick Yours today at a Reduced Price and experience the redoubtable performance of our Dissolved Oxygen Meter. Featuring an impeccable LCD Digital Display, superlative DO measurement range from 0 to 20.0 mg/L and precision accuracy of 0.4 mg/L, this handheld device is ideal for water quality testing, aquaculture, laboratories, and research. Powered by a 9V battery and equipped with a polarographic DO probe, it offers reliable manual calibration, automatic temperature compensation, and robust IP54 protection, all in a compact matte-finish ABS body. Offer valid for limited time-secure yours now from India's trusted exporter, manufacturer, supplier, and trader!

Direction of Use & Application Method

The Dissolved Oxygen Meter is specially designed for water quality testing and is used by professionals in aquaculture, laboratories, and research fields. To operate, simply power the device using a 9V battery, immerse the polarographic DO probe into the water sample, and calibrate manually as required (one or two point calibration). The automatic temperature compensation ensures accurate readings, making the process straightforward and effective for a broad range of users.


Delivery, Samples, and Transportation Details

Take advantage of our current sale price on this Dissolved Oxygen Meter, now available with efficient, secure shipping across India. We provide sample availability to help you evaluate the product's superlative performance before purchase. Orders are dispatched promptly via reliable transportation partners from our FOB port, ensuring swift delivery time for all customers. Whether for a single unit or bulk requirement, our streamlined logistics deliver satisfaction at your doorstep.


FAQ's of Dissolve oxygen meter:


Q: How do I manually calibrate the Dissolved Oxygen Meter?

A: To calibrate, use the one or two point manual calibration method instructions provided in the user guide. Regular calibration ensures precise and reliable DO measurements.

Q: What are the main applications of this DO meter?

A: This device is widely used for water quality testing in aquaculture, laboratories, and research environments, ensuring accurate analysis in diverse aquatic settings.

Q: When should I replace the DO probe or battery?

A: Replace the DO probe when readings become unstable or after extensive usage. The 9V battery should be changed once the LCD display dims or the device fails to power on.

Q: Where can I use the Dissolved Oxygen Meter safely?

A: With its IP54 protection level, the meter is suitable for use in wet laboratory and field environments, provided operating temperatures remain between 0C to 50C.

Q: What is the process for securing a sample before bulk order?

A: You can request a sample from us to evaluate the Dissolved Oxygen Meter's performance prior to finalizing a large purchase. Contact our sales team for quick processing and secure shipping.

Q: What are the benefits of automatic temperature compensation (ATC)?

A: ATC corrects DO readings for temperature fluctuations, providing superlative accuracy during all testing scenarios, regardless of environmental changes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transmitter Switch Category

Liquid level switches

Liquid level switches

Price 4500 INR / Piece

Minimum Order Quantity : 2 Pieces

Operating Temperature : 10C to +80C

Insulation Resistance : >100 M at 500V DC

Number of Module : 1

Protection Level : IP68

Rotary paddle level switches

Rotary paddle level switches

Price 8000 INR / Piece

Minimum Order Quantity : 2 Pieces

Operating Temperature : 20C to +80C

Insulation Resistance : 100 M at 500V DC

Number of Module : 1

Protection Level : IP65

Zero speed switches

Zero speed switches

Price 5500 INR / Piece

Minimum Order Quantity : 6 Pieces

Operating Temperature : 10C to +60C

Insulation Resistance : 100M at 500V DC

Number of Module : Single

Protection Level : IP65

Water level  Gauge

Water level Gauge

Minimum Order Quantity : 1 Piece

Operating Temperature : 10C to 80C

Insulation Resistance : 100 M (at 500 VDC)

Number of Module : 1

Protection Level : IP65



Back to top