Hot air woven
Hot air woven

Hot air woven

Price 10000.0 INR/ Piece

MOQ : 1 Piece

Hot air woven Specification

  • Features
  • Overheat protection, Timer, Auto cut-off, Double wall insulated
  • Equipment Type
  • Hot Air Oven
  • Temperature
  • Ambient to 300C
  • Operating Voltage
  • 230V
  • Power Supply
  • 230V AC, 50 Hz
  • Number of Specimens
  • 1-10
  • Frequency
  • 50 Hz
  • Application
  • Textile, Laboratory, Industrial Curing, Sterilization
  • Max Height
  • 600 mm (external)
  • Response Time
  • <10 seconds
  • Resolution
  • 0.1C
  • Humidity
  • 10% - 95% RH
  • Automation Grade
  • Semi-Automatic
  • Measuring Range
  • Ambient to 300C
  • Specimen Size
  • Customizable
  • Accuracy
  • 1C
  • Mounting Type
  • Floor Standing
  • Port Size
  • 4 inches diameter
  • Test Range
  • Adjustable
  • Interface Type
  • Front Panel Controls
  • Display Type
  • Digital LED Display
  • Usage
  • Material Heating, Drying, Sterilization
  • Capacity
  • 50 liters
  • Machine Weight
  • 80 kg
  • Test Speed
  • Adjustable up to 120 rpm
  • Test Width
  • 500 mm
  • Test Stroke
  • Up to 400 mm
  • Control Mode
  • Digital PID Controller
  • Heating Method
  • Sheathed Heaters
  • Door Type
  • Swing Door with Gasket
  • Insulation
  • Glass Wool Thermal Insulation
  • Safety
  • Circuit Breaker, Temperature Limit Cut-off
  • Air Circulation
  • Motorized Blower
  • Power Consumption
  • 1.2 kW
  • Color
  • Blue & Grey
  • Chamber Material
  • Stainless Steel (Inner), Mild Steel (Outer)
 

Hot air woven Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD)
  • Supply Ability
  • 70 Pieces Per Month
  • Delivery Time
  • 7 Months
  • Main Domestic Market
  • All India
 

Hot air woven About

hot air oven is a device used to dry, heat, and sterilize materials using circulating hot air. It is commonly used in laboratories for:
Dry heat sterilization of glassware (such as test tubes, flasks, and pipettes)
Drying samples and chemicals
Removing moisture from materials
Heat treatment experiments
Working principle:
An electric heater warms the air inside the chamber.
A fan (in forced-air models) circulates hot air evenly.
The hot air transfers heat to the materials placed inside.
Typical temperature range: about 50C to 300C (varies by model).
For dry heat sterilization, many laboratories use around 160180C for a specified time depending on the material and protocol.


Advanced Thermal Control for Reliable Performance

Designed for precision, this hot air oven utilizes sheathed heaters and a digital PID controller, providing finely regulated temperature from ambient up to 300C. The rapid response time and outstanding accuracy of 1C enable users to conduct consistent material heating, drying, and sterilization processes, essential for laboratory and industrial applications.


Superior Safety and Efficiency Features

With integrated overheat protection, circuit breaker, double-wall insulation, and a temperature cut-off system, the oven emphasizes safety without sacrificing efficiency. The swing door with gasket ensures a secure seal, reducing heat loss while providing easy access for specimen insertion or removal.


Flexible Operation and Customization

Operators benefit from adjustable test speed up to 120 rpm, test stroke up to 400 mm, and the ability to process 1-10 specimens with customizable sizes. The user-friendly digital interface and timer functions allow for semi-automatic operation, catering to diverse laboratory protocols or industrial workflows.

FAQ's of Hot air woven:


Q: How does the hot air oven circulate heat evenly inside the chamber?

A: Heat is uniformly distributed by a motorized blower, which circulates hot air throughout the chamber. This ensures all specimens receive consistent heating, leading to reliable and reproducible results for drying, curing, or sterilization processes.

Q: What safety mechanisms are integrated into the oven?

A: The oven is equipped with a circuit breaker, overheat protection, and a temperature limit cut-off. These features automatically interrupt operation in the event of excessive temperature or electrical faults, providing enhanced safety for users and specimens alike.

Q: When should I use the hot air oven for sterilization purposes?

A: The oven is ideal for sterilizing laboratory glassware, textile samples, and industrial components. For effective sterilization, set the recommended temperature (commonly above 160C) and duration as per your application's protocol using the digital PID controller.

Q: Where is the optimal location to install the hot air oven?

A: It is best mounted on a stable floor surface in a well-ventilated laboratory or industrial area, ensuring unobstructed access to the front panel controls and sufficient clearance for airflow around the device. Avoid placing it near flammable materials or sources of water.

Q: What control options are available for adjusting test parameters?

A: Users can adjust temperature, timer, test speed (up to 120 rpm), test stroke (up to 400 mm), and specimen number from the digital front panel interface. These adjustable settings provide granular control for a variety of heating and testing processes.

Q: How does the double-wall insulation benefit the oven's performance?

A: The advanced glass wool thermal insulation between the stainless steel chamber and mild steel outer wall significantly minimizes heat loss, enhances energy efficiency, and keeps the external surface temperature safer to touch during operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pressure Instruments Category

Yokogawa Pressure Transmitter

Yokogawa Pressure Transmitter

Minimum Order Quantity : 1 Piece

Display Type : LCD

Features : SIL 2/3 certification

Mounting Type : IP67

Equipment Type : Pressure Transmitter

Wika Pressure Gauges And Switches

Wika Pressure Gauges And Switches

Minimum Order Quantity : 1 Piece

Display Type : Analog Dial With Pointer

Mounting Type : Panel/Surface

Application : Industrial process control

Danfoss Pressure Switch

Danfoss Pressure Switch

Minimum Order Quantity : 1 Piece

Application : Automatic PressureBased Control

Equipment Type : Pressure Switch

Dwyer Magnehelic Differential Pressure Gauge

Dwyer Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 1 Piece

Display Type : Analog EasytoRead Dial

Features : Shock & Vibration Resistant

Mounting Type : Wall Mount



Back to top