Muffle furnace
Muffle furnace

Muffle furnace

Price 20000.0 INR/ Unit

MOQ : 1 Piece

Muffle furnace Specification

  • Air Flow
  • Static (no airflow)
  • Type
  • Electrical Laboratory Furnace
  • Frame Material
  • MS powder coated
  • Floor
  • Ceramic or refractory brick
  • Lighting
  • No interior lighting
  • Application
  • Ashing, material testing, heat treatment, ceramics
  • Door
  • Front-load, insulated door with handle
  • Dimension (L*W*H)
  • Approx. 420 x 450 x 600 mm
  • Thickness
  • High-density insulation, approx. 100 mm
  • Power Consumption
  • 2-6 kW, depending on model
  • Material
  • Mild steel exterior, ceramic insulation
  • Condition
  • New
  • Weight
  • Approx. 35-50 kg
  • Feature
  • Temperature controller, digital display, safety interlock
  • Voltage
  • 220-240V AC
  • Stand
  • Integrated legs with rubber footing
  • Display
  • Digital LED/LCD
  • Temperature Uniformity
  • 5C
  • Insulation Material
  • Ceramic fibre wool
  • Safety Features
  • Over-temperature alarm, safety cut-off
  • Heating Element
  • Kanthal A1 or similar resistance wire
  • Controller Type
  • Microprocessor-based PID Digital temperature controller
  • Body Finish
  • Powder-coated corrosion resistant
  • Fuse Protection
  • Yes
  • Operation Mode
  • Manual or programmable
  • Maximum Temperature
  • Up to 1200C or 1400C depending on model
  • Internal Chamber Size
  • 150 x 150 x 300 mm (varies per model)
 

Muffle furnace Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD)
  • Supply Ability
  • 20 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

Muffle furnace About

Muffle furnace is a laboratory or industrial furnace used to heat materials to very high temperatures while keeping the sample isolated from direct contact with flames, fuel, or combustion gases. Modern muffle furnaces are usually electrically heated and provide uniform, controlled heating. 

Common applications:

  • Ash content determination
  • Heat treatment of metals
  • Calcination of chemicals
  • Ceramic and glass processing
  • Sintering materials
  • Burning off organic matter in laboratory samples 
Typical features:
  • Temperature range: 9001800C (depending on the model)
  • Digital PID temperature controller
  • Ceramic fiber insulation for efficient heating
  • Uniform temperature distribution
  • Safety features such as over-temperature 
  • Working principle: Electrical heating elements surrounding an insulated chamber generate heat. The sample is placed inside the chamber, where it is heated by radiation and convection rather than by direct flame, ensuring clean and accurate thermal


Precise Temperature Control and Uniformity

Our muffle furnace is engineered to deliver exceptional temperature regulation, featuring a microprocessor-based PID controller and uniform heating within 5C. The LED/LCD display ensures real-time monitoring, making it suitable for sensitive laboratory procedures and consistent heat treatments.


Advanced Safety and Durability

Safety features such as over-temperature alarm, automatic safety cut-off, and robust fuse protection provide peace of mind during high-temperature operations. High-density ceramic insulation and a corrosion-resistant powder-coated body enhance durability, while an insulated front-load door and rubber-footed stand ensure safe, convenient usage.

FAQ's of Muffle furnace:


Q: How does the microprocessor-based PID controller improve temperature stability in the muffle furnace?

A: The microprocessor-based PID digital controller continually monitors and adjusts the heating process, minimizing temperature fluctuations and ensuring precise and stable temperatures throughout the chamber. This optimizes performance for demanding laboratory and industrial processes.

Q: What safety features are included to protect users and the furnace during operation?

A: Key safety features include an over-temperature alarm, automatic safety cut-off, fuse protection, and a securely insulated door. These protect both users and the furnace by preventing overheating and accidental exposure to high temperatures.

Q: When should I choose a manual versus programmable operation mode for the furnace?

A: Manual mode is suitable for straightforward heating applications with minimal parameter adjustments. Programmable mode is ideal for complex protocols requiring precise control over temperature ramp rates and hold times, such as material testing or multi-stage heat treatments.

Q: Where can this muffle furnace be installed and used effectively?

A: This furnace is designed for laboratory or industrial environments with stable 220-240V AC supply and good ventilation. It is often used in research institutes, material science labs, ceramic studios, and quality control departments.

Q: What is the process for routine maintenance of the muffle furnace?

A: Regular maintenance involves removing accumulated debris, gently cleaning the ceramic insulation and heating elements, inspecting electrical connections, and checking the integrity of safety features. Always ensure the furnace is powered off and cool before performing any service.

Q: What are the key benefits of using Kanthal A1 heating elements and ceramic fibre insulation?

A: Kanthal A1 elements ensure efficient, long-lasting heat generation, while ceramic fibre wool and high-density insulation provide excellent thermal retention, reduce energy loss, and extend the furnace's operational life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Room Monitoring System Category

Duct Air Velocity and Volumn Sensor

Duct Air Velocity and Volumn Sensor

Minimum Order Quantity : 1 Unit

Type : Other , Duct Air Velocity & Volume Sensor

Condition : Other, New

Material : Other, ABS Plastic Housing

Power Consumption : < 2 VA

Voltage : 24 V AC/DC

Greystone Duct Smoke Detector

Greystone Duct Smoke Detector

Minimum Order Quantity : 1 Unit

Type : Other , Duct Smoke Detector

Condition : Other, New

Material : Other, Highimpact plastic housing

Power Consumption : Low power consumption

Voltage : 24 VAC/DC or 120/240 VAC (Model dependent)

Differential Pressure Transmitter DPT

Differential Pressure Transmitter DPT

Minimum Order Quantity : 1 Unit

Type : Other , Differential Pressure Transmitter

Condition : Other, New

Material : Other, ABS Plastic Body

Power Consumption : 2 W (Maximum)

Voltage : 24 V DC

Rotronic Duct Humidity And Temperature Transmitter

Rotronic Duct Humidity And Temperature Transmitter

Minimum Order Quantity : 1 Piece

Type : Other , Humidity and Temperature Transmitter



Back to top